  Model  | 
 PKL-280H  | 
| 
  Applicable fibers  | 
  SM (ITU-T G.652), MM (ITU-T G.651), DS (ITU-T G.653), NZDS (ITU-T G.655)  | 
| 
  Fiber cleaved length  | 
  8~16mm (Coating diameter: 250µm) 
 16mm (Coating diameter: 250-1000um)  | 
| 
  Fiber diameter  | 
  Cladding diameter: 80 -150um 
 Coating diameter: 100- 1000um  | 
| 
  Fiber Count  | 
  Single  | 
| 
  Fiber aligning method  | 
  Core aligning  | 
| 
 | 
 | 
| 
  Actual average splice loss  | 
   0.02dB (SM), 0.01dB (MM),  
  0.04dB (DS), 0.04dB( NZDS)   | 
| 
  Splicing mode  | 
   auto  | 
| 
  Splicing mode  | 
  12(templet), 188(user)  | 
| 
 | 
 Typical 9 sec, with standard SM fiber   | 
| 
  Protection sleeve length  | 
 60mm, 40mm and a series of micro sleeves   | 
| 
 | 
 5000 results, 3 parameter per result   | 
| 
 | 
 | 
 Fiber display and magnification   | 
 400X (X or Y view), 200X (X and Y view)   | 
| 
 | 
 | 
| 
  Electrode life  | 
  2500  | 
| 
  No.of splice/heating with battery  | 
  Typical 130 cycles (splice/tube heat) with inner Li-battery  | 
| 
  Display screen  | 
  5 inch color LCD monitor  | 
| 
  Image change over  | 
  The fiber image is turned upside down  | 
| 
  Terminals  | 
  RS 232  | 
| 
  Operating condition  | 
  0 - 5000m above sea level,  0 - 95%RH and -10 - 50 deg, respectively,  Max. wind velocity of 15m/s  | 
| 
  Power supply  | 
  AC 100-240V with AC adapter; inner Li-battery(6600mAH)  | 
| 
  Dimensions  | 
  150mm(L) x150mm (W) x160mm (H)  | 
| 
  Weight  | 
  3.52 Kg including battery  |